Imaging
  Microplate Reader
  Liquid Handler
  Robotics
  Software Products
We provide our excellent experiences to our customer
Microplate Instruments > > Imaging
 
Cytation 5 ¼¼Æ÷ À̹Ì¡ ¸ÖƼ ¸ðµå ¸®´õ

¡Ø °í°´´ÔÀÇ ¸ð´ÏÅÍ Çػ󵵿¡ µû¶ó »óÇ°»ö»óÀÌ Á¶±Ý¾¿ ´Þ¶óÁú ¼ö ÀÖ½À´Ï´Ù.
Cytation 5 ¼¼Æ÷ À̹Ì¡ ¸ÖƼ ¸ðµå ¸®´õ
  
   ÆäÀ̽ººÏ   Æ®À§ÅÍ
 
Cytation 5 ¼¼Æ÷ À̹Ì¡ ¸ÖƼ ¸ðµå ¸®´õ Á¦Ç°»ó´ã¹®ÀÇ

°³¿ä

Cytation¢â 5 is a uniquely integrated, configurable system that combines automated digital widefield microscopy with conventional multi-mode microplate detection to provide phenotypic cellular information and well-based quantitative data. This single instrument platform replaces multiple modules and software interfaces, yet is simple to setup and operate. With up to 60x magnification, the microscopy module provides high-quality cellular and sub-cellular visualization in fluorescence, brightfield, H&E and phase contrast channels. The multi-mode detection module features BioTek¡¯s patented Hybrid Technology¢â, which incorporates variable bandwidth monochromator optics and high sensitivity filter-based detection optics for unmatched versatility and performance. Temperature control to 65 ¡ÆC and shaking, plus available CO2/O2 control and dual reagent injectors optimize conditions for cell-based imaging and detection. Image capture, data collection and powerful image and data analysis are managed with Gen5¢â software, specifically designed for uncomplicated processing of even the most complex assays.
 

Visit the Cytation site to learn more about imaging & microscopy features and applications with Cytation Cell Imaging Multi-Mode Readers.

±â´É

  • Fluorescence, brightfield, H&E and phase contrast microscopy and conventional multi-mode detection provides powerful imaging and quantitative data collection in one instrument
  • Patented Hybrid Technology¢â, in multi-mode detection combines high performance filters with variable bandwidth monochromators for versatility and performance
  • The fluorescence monochromators offer a variable bandwidth from 9 nm to 50 nm in 1 nm increments for ultimate flexibility
  • Laser-based excitation for AlphaScreen¢ç / AlphaLISA¢ç assays
  • CO2/O2 control, incubation to 65 ¡ÆC and shaking optimize cell-based and other assays
  • Low volume (2 µL) nucleic acid and protein quantification with the available Take3 Plates
  • Powerful yet easy to use Gen5 software for efficient plate reading, image capture and analy
  • Imaging Plus ¸ÖƼ ¸ðµå ±¸¼º Á¦Ç°

    »ó¼¼ ¸ðµ¨#
    CYT5FV
    CYT5FAV
    CYT5MV
    CYT5MPV
    CYT5MFV
    CYT5MFAV
    À̹Ì¡      
    Çü±¤ À̹Ì¡
    ¸í½Ã¾ß À̹Ì¡
    H&E À̹Ì¡
    À§»óÂ÷ À̹Ì¡   
      
    ÇÊÅÍ ±â¹Ý      
    Çü±¤ °­µµ
     
     
    Çü±¤ Æí±¤
     
     
    ½Ã°£ ºÐ¼® Çü±¤
     
     
    ¿©°úµÈ ¹ß±¤
     
     
    Alpha ŽÁö
     
     
     
     
    ¸ð³ëÅ©·Î¸ÞÅÍ ±â¹Ý      
    Àڿܼ± °¡½Ã±¤ Èí±¤  
    Çü±¤ °­µµ  
    ½Ã°£ ºÐ¼® Çü±¤ (ºÎ¼öÀûÀÎ)  
    ¹ß±¤  
    ±âŸ      
    Take3 Ç÷¹ÀÌÆ®¿Í ȣȯ  


    À̹Ì¡ Àü¿ë ¹× ¸ÖƼ ¸ðµå Àü¿ë ±¸¼º Á¦Ç°

    »ó¼¼ ¸ðµ¨ #
    CYT5V
    CYT5PV
    CYT5MFCYT5MFACYT5FCYT5FACYT5M
    À̹Ì¡       
    Çü±¤ À̹Ì¡
     
        
    ¸í½Ã¾ß À̹Ì¡
     
        
    H&E À̹Ì¡
     
        
    À§»óÂ÷ À̹Ì¡ 
         
    ÇÊÅÍ ±â¹Ý       
    Çü±¤ °­µµ
     
     
     
    Çü±¤ Æí±¤
     
     
     
    ½Ã°£ ºÐ¼® Çü±¤
     
     
     
    ¿©°úµÈ ¹ß±¤
     
     
     
    Alpha ŽÁö
     
     
     
     
     
    ¸ð³ëÅ©·Î¸ÞÅÍ ±â¹Ý       
    Àڿܼ± °¡½Ã±¤ Èí±¤  
      
    Çü±¤ °­µµ  
      
    ½Ã°£ ºÐ¼® Çü±¤ (ºÎ¼öÀûÀÎ)  
      
    ¹ß±¤  
      
    ±âŸ       
    Take3 Ç÷¹ÀÌÆ®¿Í ȣȯ  
      

    ¸ðµç Á¦Ç°Àº 65 ¡ÆC ¹è¾ç, ½¦ÀÌÅ·ÀÌ °¡´ÉÇϸç, BioTekÀÇ Dual Reagent Injection Module, CO2/O2 °¡½º Á¦¾î Àåºñ ¹× BioStack ¸¶ÀÌÅ©·ÎÇ÷¹ÀÌÆ® ½ºÅÂÄ¿¿Í ȣȯÀÌ °¡´ÉÇÕ´Ï´Ù.

    »ó¼¼±Ô°Ý

    ÀϹÝÀûÀÎ
    °ËÃâ ¸ðµå AlphaScreen/AlphaLISA
    Çü±¤ °­µ¿
    Çü±¤ Æí±¤
    ½Ã°£ ºÐÇØ Çü±¤
    Èí±¤
    ¹ß±¤
    ¸¶ÀÌÅ©·ÎÇ÷¹ÀÌÆ® ŸÀÔ6- ~ 384-well Ç÷¹ÀÌÆ®
    ´Ù¸¥ ½ÇÇè½Ç¿ë ±â±¸Çö¹Ì°æ ½½¶óÀ̵å, ÆäÆ®¸® µð½¬, ¼¼Æ÷ ¹è¾ç Çöó½ºÅ© (T25), Take3¢â ¸¶ÀÌÅ©·Î º¼·ý Ç÷¹ÀÌÆ®¿Í ȣȯ °¡´É
    ¿Âµµ Á¦¾î°á·Î Á¦¾î¸¦ °¡Áø 65 ¡ÆC ±îÁöÀÇ 4-Zone ¹è¾ç; 37 ¡ÆC¿¡¼­ +0.2 ¡ÆC ÆíÂ÷
    ½¦ÀÌÅ·¼±Çü, ±ËµµÇü, ÀÌÁß ±ËµµÇü
    ¼ÒÇÁÆ®¿þ¾îGen5¢â µ¥¾îÅÍ ºÐ¼® ¼ÒÇÁÆ®¿þ¾î
    ÀÚµ¿È­BioStack ¹× Ÿ»ç ÀÚµ¿È­ Àåºñ¿Í ȣȯ °¡´É
    CO2 ¹× O2 Á¦¾î¹üÀ§: 0 - 20% (CO2); 1 - 19% (O2) ÇØ»óµµ Á¦¾î: +0.1% (CO2 and O2) ¾ÈÁ¤¼º: +0.2% at 5% CO2; +0.2% at 1% O2
    CO2 ¿Í O2 µÎ°¡Áö ´Ù ÀÖ´Â ¸ðµ¨ ȤÀº CO2 ¸¸ ÀÖ´Â ¸ðµ¨ÀÌ ÀÖ½À´Ï´Ù.
    ºû ±Ù¿øÁ¦³í Ç÷¹½¬ - Çü±¤ ¹× Èí±¤
    100 mW ·¹ÀÌÁ® - AlphaScreen/AlphaLISA
    À̹ÌÁö ½Ã½ºÅÛ
    Ä«¸Þ¶ó16-bit ±×·¹ÀÌ ½ºÄÉÀÏ, ¼Ò´Ï CCD, 1.1 ¸Þ°¡ Çȼ¿
    À̹ÌÁö ¸ðµåÇü±¤
    ¸í½Ã¾ß
    À§»óÂ÷
    H&E À̹Ì¡
    À̹ÌÁö ±â¹ý´Ü»ö, ¸ÖƼ Ä÷¯, ¸ùŸÁÖ, Àú¼Ó ÃÔ¿µ, Z-½ºÅÂÅ·
    ¿µ»ó ó¸®Z-Åõ»ç, µðÁöÅÐ À§»óÂ÷, ½ºÆ¼Äª
    À§Ä¡ Á¦¾îÁ¶À̽ºÆ½ Á¦¾î
    ¼ÒÇÁÆ®¿þ¾î Á¦¾î
    ÀÚµ¿È­µÈ ±â´É»ç¿ëÀÚ Á¶Á¤ ÀÚµ¿ ÃÊÁ¡, ÀÚµ¿ ÃÊÁ¡, ÀÚµ¿ ³ëÃâ, ÀÚµ¿ LED °¨µµ
    À̹Ì¡ ÇÊÅÍ Å¥ºê ¼ö¿ë·Â4°³ÀÇ ¿Âº¸µå, »ç¿ëÀÚ°¡ ±³Ã¼ÇÒ ¼ö ÀÖ´Â ÇÊÅÍ Å¥ºê
    À̹Ì¡ ÇÊÅÍ Å¥ºê °¡´ÉDAPI, CFP, GFP, YFP, RFP, Texas Red, CY5, CY7, Acridine Orange (ACR OR), CFP-YFP FRET, propidium Iodide, chlorophyll, phycoerythrin
    À̹Ì¡ LED Å¥ºê °¡´É365 nm, 405 nm, 465 nm, 590 nm, 523 nm, 505 nm, 623 nm, 740 nm
    ´ë¹°·»Áî ¼ö¿ë·Â»ç¿ëÀÚ°¡ ±³Ã¼ÇÒ ¼ö ÀÖ´Â 6°³ÀÇ ´ë¹°·»Áî
    ÀÌ¿ë °¡´ÉÇÑ ´ë¹°·»Áî2.5x, 4x, 10x, 20x, 40x, 60x
    ´Ü°èÀû ´ë¹°·»Áî4x, 10x, 20x, 40x
    À̹ÌÁö ¼öÁý ¼Óµµ96 wells, 1 Ä÷¯ (DAPI), 4x, 6 ºÐ
    96 wells, 3 Ä÷¯, 4x, 12 ºÐ
    Çü±¤ °­µµ
    °¨µµ¸ð³ëÅ©·Î¸ÞÀÌÅä:
    »ó´Ü: Ç÷ç¿À·¹¼¼ÀÎ 2.5 pM (0.25 fmol/well 384-well Ç÷¹ÀÌÆ®)
    ÇÏ´Ü: Ç÷ç¿À·¹¼¼ÀÎ 4 pM (0.4 fmol/well 384-well Ç÷¹ÀÌÆ®)

    ÇÊÅÍ/°Å¿ï:
    Ç÷οÀ·¹¼¼ÀÎ 0.25 pM (0.025 fmol/well 384-well Ç÷¹ÀÌÆ®)
    ÆÄÀå ¼±Åà 4Áß ¸ð³ëÅ©·Î¸ÞÅÍ (»ó´Ü/ÇÏ´Ü) ¹× ±íÀº ÀúÁö Çö»ó (µö ºí·ÎÅ·) ´ë¿ª ÇÊÅÍ/»ö¼±º° °Å¿ï (»ó´Ü)
    ÆÄÀå ¹üÀ§ ¸ð³ëÅ©·Î¸ÞÅÍ: 250 - 700 nm (¿É¼Ç : 850 nm)
    ÇÊÅÍ: 200 - 700 nm (¿É¼Ç : 850 nm)
    ¸ð³ëŬ·Î¸ÞÅÍ ´ë¿ª¹üÀ§°¡º¯Àû, 9 nm ~ 50 nm, 1 nm ´ÜÀ§·Î Áõ°¡
    °ËÃ⠽ýºÅÛ 2°³ÀÇ PMT Ž»ö±â: ¸ð³ëÅ©·Î¸ÞÀÌÅÍ ½Ã½ºÅÛ 1°³, ÇÊÅÍ ½Ã½ºÅÛ 1°³
    µ¿Àû ¹üÀ§ 7 decades
    ¹ß±¤
    °¨µµ¸ð³ëÅ©·Î¸ÞÀÌÅÍ ½Ã½ºÅÛ: 20 amol ATP (Ç÷¹½¬)
    ÇÊÅÍ ½Ã½ºÅÛ: 10 amol ATP (Ç÷¹½¬)
    100 amol (glow)
    ÆÄÀå ¹üÀ§ 300 - 700 nm
    µ¿Àû ¹üÀ§ >6 decades
    Çü±¤ Æí±¤
    °¨µµ1 nM Ç÷ç¿À·¹¼¼Àο¡¼­ 1.2 mP Ç¥ÁØ ÆíÂ÷
    ÆÄÀå ¹üÀ§ 280 - 700 nm (¿É¼Ç 850 nm)
    ½Ã°£ ºÐÇØ Çü±¤
    °¨µµÇÊÅ͸¦ °¡Áø Europium 40 fM (4 amol/well in 384-well Ç÷¹ÀÌÆ®)
    ¸ð³ë¸¦ °¡Áø Europium 1200 fM (120 amol/well in 384-well Ç÷¹ÀÌÆ®)
    ÆÄÀå ¹üÀ§ ¸ð³ë: 250 - 700 nm (¿É¼Ç : 850 nm)
    ÇÊÅÍ: 200 - 700 nm (¿É¼Ç : 850 nm)
    Èí±¤
    ÆÄÀå ¼±Åà ¸ð³ëÅ©·Î¸ÞÀÌÅÍ
    ÆÄÀå ¹üÀ§ 230 - 999 nm, 1 nm ¾¿ Áõ°¡
    ´ë¿ªÆø4 nm (230 - 285 nm), 8 nm (>285 nm)
    µ¿Àû ¹üÀ§ 0 - 4.0 OD
    ÇØ»óµµ0.0001 OD
    ½Ã¾à ÁÖÀÔ±â
    ³Ñ¹ö2°³ÀÇ ½Ç¸°Áö ÆßÇÁ
    ŽÁö ¸ðµå Áö¿ø¸ðµç ¸ðµ¨
    ºÐÁÖ ¿ë·® 5 - 1000 µL (1 µL ¾¿ Áõ°¡)
    ¾²ÀÌÁö ¸øÇÏ´Â ¿ë·®1 mL, ¹é Ç÷¯½ÌÀ» °¡Áø 100 µL
    Ç÷¹ÀÌÆ® Çü»ó6- ~ 384-well ¸¶ÀÌÅ©·ÎÇ÷¹ÀÌÆ®, ÆäÆ®¸® µð½¬
    ºÐÁÖ Á¤È®¼º 50 - 200 µL ¿¡¼­ <2%
    ºÐÁÖ Á¤È®µµ +1 µL ¶Ç´Â 2%
    ¾ËÆÄ Å½Áö
    ±¤¿ø 680 nm ·¹ÀÌÀú, 100 mW
    ÆÄÀå ¼±ÅÃÇÊÅÍ (»ó´Ü)
    ¹Î°¨µµ100 amol LCK peptide (384-well low volume plate)
    ¹°¸®Àû Ư¼º
    ÆÄ¿öÃÖ´ë 250 ¿ÍÆ®
    ¸éÀû20" D x 16.5" W x 17.5" H (50.8 cm x 41.91 cm x 44.5 cm)
    ¹«°Ô80 lbs (36.3 Kg)
    Á¶Àý
    Á¶ÀýCE & TUV ¸¶Å© Ç¥½Ã. RoHS Áؼö. ü¿ÜÁø´Ü¿ëÀ¸·Î »ç¿ë °¡´ÉÇÑ ¸ðµ¨.

    »ç¾çÀº º¯°æµÉ ¼ö ÀÖ½À´Ï´Ù. ¼º´É °ªÀº Æò±Õ °üÃø ¿ä¼Ò Å×½ºÆ® °ªÀ» ³ªÅ¸³À´Ï´Ù







    ÀÚ¼¼ÇÑ »çÇ×Àº ¾Æ·¡ ÁÖ¼Ò·Î È®ÀÎ °¡´ÉÇÕ´Ï´Ù.

    http://www.biotekinstruments.co.kr/ko/products/imaging/cytation5_cell_imaging_multi_mode_reader.html